{"product_id":"growlink-4-triac-out-module","title":"Growlink 4 Triac Out Module","description":"\u003ch2\u003e4-Channel Triac Output Module for Fast-Cycling Dosing Loads\u003c\/h2\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe BMT-F-TO4 carries four solid-state triac outputs rated \u003cstrong\u003e0.8 A each at 24 V AC\/DC\u003c\/strong\u003e. Where a DO-4 relay would burn out chasing the rapid pulses an HE Anderson injection pump asks for, the triac switches stay clean. The pump fires rhythmically at the injection rate the dosing recipe calls for, and BACnet MS\/TP carries the setpoints from the Growlink controller.\u003c\/p\u003e\n\u003ch2\u003eBACnet MS\/TP Triac Module with Manual Override on Every Channel\u003c\/h2\u003e\n\u003cp style=\"text-align: justify;\"\u003eEach output gets a three-position black toggle. Setting \u003cstrong\u003eA\u003c\/strong\u003e lets Growlink software command the channel. Setting \u003cstrong\u003e1\u003c\/strong\u003e forces the triac on. Setting \u003cstrong\u003e0\u003c\/strong\u003e locks it off. The module clips to a TH35 DIN rail and lands the BACnet line on spring-clamp terminals, so commissioning takes minutes per panel. Wire it next to a BMT-F-DI4 or BMT-F-AOP4 for a full BACnet I\/O stack on the same trunk.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 triac outputs at 0.8 A:\u003c\/strong\u003e Solid-state switching for fast-cycling AC loads like HE Anderson dosing pumps and small solenoid valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBACnet MS\/TP communication:\u003c\/strong\u003e Plugs into the Growlink controller and any other BACnet trunk without protocol gateways.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual A\/1\/0 toggle per channel:\u003c\/strong\u003e Switch from software control to forced on or forced off without rewiring the panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 V AC\/DC supply:\u003c\/strong\u003e Pairs with the same low-voltage bus that runs the rest of the BMT-F I\/O lineup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTH35 DIN rail mount:\u003c\/strong\u003e Spring-clamp terminals snap into IEC 60715 rail for clean panel build-outs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo mechanical relays to wear out:\u003c\/strong\u003e Triac switching handles the rapid pulse trains a relay would burn out on inside a season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStackable with BMT-F-DI4 \/ BMT-F-AOP4 \/ BMT-F-RTR:\u003c\/strong\u003e Build a full BACnet MS\/TP I\/O bank on one trunk with the Metz Connect family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: justify;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #333; color: #fff;\"\u003e\n\u003cth style=\"padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eOEM module\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eMetz Connect BMT-F-TO4 (P\/N 1108801370)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eBACnet MS\/TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eOutputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e4 × solid-state triac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eOutput rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e0.8 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eSupply voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eManual override\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e3-position toggle per channel (A \/ 1 \/ 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eTerminals\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eSpring-clamp blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eTH35 DIN rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eTypical use\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHE Anderson dosing pumps, solenoid valves, contactor coils, AC loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eCompanion modules\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eBMT-F-DI4, BMT-F-AOP4, BMT-F-CI4, BMT-F-RTR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Growlink","offers":[{"title":"Default Title","offer_id":48240788537558,"sku":"BMT-F-TO4 BACnet MS\/TP","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/9450\/6454\/files\/Growlink_4_Triac_Out_Module_main_image.webp?v=1778793794","url":"https:\/\/growershouse.com\/products\/growlink-4-triac-out-module","provider":"GrowersHouse","version":"1.0","type":"link"}