{"product_id":"growlink-batch-tanklink-temperature-sensor","title":"Growlink Batch TankLINK Temperature Sensor","description":"\u003ch2\u003eReal-Time Nutrient Reads with the Growlink Batch TankLINK Temperature Sensor\u003c\/h2\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe \u003cstrong\u003eGrowlink Batch TankLINK Temperature Sensor\u003c\/strong\u003e reads nutrient solution temperature directly inside a batch tank or reservoir. The probe ties into the Batch TankLINK controller's screw terminal block. It reports continuously at \u003cstrong\u003e0.02°F resolution\u003c\/strong\u003e with \u003cstrong\u003e±3.6°F (±2°C) accuracy\u003c\/strong\u003e. The controller itself operates from \u003cstrong\u003e50 to 122°F\u003c\/strong\u003e. That range covers the 68–72°F target band most hydroponic crops respond best to inside the root zone. Drop the probe into calibration solution alongside the pH and EC probes during the LCD wizard. It locks in for the run.\u003c\/p\u003e\n\u003ch2\u003eWiring the TankLINK Temperature Probe into a Live Recirculation Loop\u003c\/h2\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe sensor handles the temperature input on a controller that already measures pH, EC, and tank level on the same board. Growers usually position this TankLINK temperature probe near the recirculation return so the reading reflects what plants actually receive. Pair it with a chiller or in-line heater triggered by the TankLINK. The nutrient solution temperature probe data then holds tighter to setpoint through lights-on heat spikes. On drain-to-waste schedules, the temperature read alongside EC tells you whether morning-shot solubility issues are temperature-driven. That separates a chiller problem from a recipe problem before you adjust the feed. Plug-and-play wiring keeps a single-probe swap during teardown to a few minutes. No driver shuffling — just the batch tank temperature probe back into the terminal block and a quick recalibrate. Most rooms keep one spare on hand for summer runs when reservoir temps climb hardest, particularly in greenhouses without dedicated cooling.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e±3.6°F (±2°C) Accuracy:\u003c\/strong\u003e Tight enough to confirm the nutrient line stays inside the 68–72°F sweet spot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.02°F Resolution:\u003c\/strong\u003e Picks up small drifts during lights-on spikes before they widen into a real swing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect TankLINK Integration:\u003c\/strong\u003e Wires straight into the Batch TankLINK controller's labeled screw terminal block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Wizard Compatible:\u003c\/strong\u003e Drops into the LCD wizard alongside pH and EC for a single calibration pass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-Play Replacement:\u003c\/strong\u003e Probe swap during teardown takes minutes — terminal block in, recalibrate, run.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: justify;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #333; color: #fff;\"\u003e\n\u003cth style=\"padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e±3.6°F (±2°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e0.02°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eController Operating Range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e50–122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eScrew terminal block (labeled on transmitter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eCompatible Controller\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eGrowlink Batch TankLINK (pH, EC, Temp, Level inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eCalibration\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eLCD wizard, paired with pH \u0026amp; EC probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e24VDC via TankLINK controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Growlink","offers":[{"title":"Default Title","offer_id":48240874815702,"sku":"GL-LINK-TEMPSENSOR","price":44.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/9450\/6454\/files\/Growlink_Batch_TankLINK_Temperature_Sensor.webp?v=1778625808","url":"https:\/\/growershouse.com\/products\/growlink-batch-tanklink-temperature-sensor","provider":"GrowersHouse","version":"1.0","type":"link"}