{"product_id":"trolmaster-240v-co2-device-station-co2-control-relay-single-pack-with-cable-set-dsc-2","title":"TrolMaster DSC-2 240V CO2 Device Station | 10A Relay for Hydro-X","description":"\u003ch2\u003eTrolMaster DSC-2 Brings 240V CO2 Equipment Under Hydro-X Control\u003c\/h2\u003e\u003cp style=\"text-align: justify;\"\u003eThe DSC-2 is a plug-in relay module that sits between a CO2 device and a 240V receptacle. Your Hydro-X controller turns it on and off over an RJ12 cable, based on its CO2 sensor reading and your settings. It accepts \u003cstrong\u003e100–240VAC at 50\/60Hz\u003c\/strong\u003e and passes that same voltage to the load, up to \u003cstrong\u003e10A\u003c\/strong\u003e of output current. TrolMaster's plug chart lists it as the US 240V version of the CO2 station, with the DSC-1 covering 120V rooms. Supplemental CO2 devices and CO2 exhaust controls both fit the job. The box holds the module, a \u003cstrong\u003e16 ft\u003c\/strong\u003e and a \u003cstrong\u003e4 ft\u003c\/strong\u003e RJ12 cable, and an RJ12 T-splitter for daisy-chaining modules. A small address button links it to the main controller the first time you power it up. On the DS module family, a solid green LED means the output is on, and blinking red means the load tripped the overload. The module measures 3.35 × 3.15 × 3.54 in and ships at 0.84 lbs. It is rated for rooms between 32 and 122°F at up to 90% relative humidity.\u003c\/p\u003e\u003ch2\u003eWhere a 240V CO2 Device Station Fits in the Room\u003c\/h2\u003e\u003cp style=\"text-align: justify;\"\u003eMost growers plug the module in right at the receptacle that feeds the CO2 equipment, then run the RJ12 line back to the controller. Keep it off the floor and away from the reservoir, since the housing is a plug-in module and not a sealed enclosure. The controller does the thinking here. Set it to hold CO2 only during the light period and to stop injecting whenever the exhaust fans come on. Without that interlock, you end up paying to vent enriched air straight out of the room. The overload indicator earns its keep when a new piece of gear draws more than expected on start-up. If it trips, unplug the module to reset it, then check the load before plugging it back in. Most CO2 regulators and burner igniters in hobby rooms run on standard household voltage, so check the nameplate first. For anything that draws past the module's rating, drive a contactor with it rather than the device directly. In rooms already wired for high-voltage lighting and HVAC, it keeps CO2 on the same controller and the same schedule as everything else.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e240V US Version:\u003c\/strong\u003e Pairs with 240V CO2 equipment, while the DSC-1 handles 120V rooms on the same system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10A Output:\u003c\/strong\u003e Covers typical supplemental CO2 devices and exhaust controls without an extra relay in between.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRJ12 Plug and Play:\u003c\/strong\u003e The controller link runs over the included cables, and a T-splitter lets modules share one line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Button and LED:\u003c\/strong\u003e One press links it to the controller, and the LED shows standby, on, or overload at a glance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Protection:\u003c\/strong\u003e A blinking red LED flags an overloaded output, and unplugging the module resets it.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333; color:#fff;\"\u003e\n\u003cth style=\"padding:8px; text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color:#fff;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003ePart number\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eDSC-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eCompatible controllers\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eTrolMaster Hydro-X (HCS-1, HCS-2, HCS-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#fff;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e100–240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutput voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e100–240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#fff;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutput current\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003ePlug version\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eUS 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#fff;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e32–122°F, ≤90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003ePackage contents\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eCO2 Device Station, 16 ft RJ12 cable, 4 ft RJ12 cable, RJ12 T-splitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#fff;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e3.35 × 3.15 × 3.54 in (85 × 80 × 90 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e0.84 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"TrolMaster","offers":[{"title":"Default Title","offer_id":50527961579734,"sku":"DSC-2","price":87.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/9450\/6454\/files\/trolmaster-dsc-2-main-v1.webp?v=1790264231","url":"https:\/\/growershouse.com\/products\/trolmaster-240v-co2-device-station-co2-control-relay-single-pack-with-cable-set-dsc-2","provider":"GrowersHouse","version":"1.0","type":"link"}