Myron L Ultrapen PT1 Conductivity, TDS and Salinity Pen
The Ultrapen PT1 from Myron L Company packs four water measurements into a slim pen. It reads conductivity, total dissolved solids, salinity and temperature from a single sample. Conductivity runs from 1 to 10,000 microsiemens, which is 0.001 to 10 mS/cm. TDS covers 1 to 10,000 ppm, and salinity covers 0.0010 to 10.000 parts per thousand. Resolution is 0.1 µS or ppm below 100 and 1 µS or ppm above it. After a wet calibration, accuracy is ±1% of reading, or ±0.2% at the calibration point. Readings settle in 10 to 20 seconds. Automatic temperature compensation corrects every reading to 25°C, and the built-in thermometer reads 32 to 160°F to 0.1 degree. Five solution modes let the pen model different waters, including KCl, the Myron L 442 natural water standard and sodium chloride. The case is anodized aircraft aluminum with fully encapsulated electronics. It carries IP67 and NEMA 6 ratings for water resistance. The pen measures 6.75 inches long, weighs 55 grams and is made and assembled in the USA.
Taking Nutrient EC Readings with the PT1
Most growers set the pen to KCl mode for nutrient EC readings, since feed charts are usually written in mS/cm or µS. Growers who follow ppm charts can switch to a TDS mode and match the conversion used by their nutrient brand. To measure, press the button and dip the sensor end into the sample, or fill the included scoop. Hold the pen still until the reading stabilizes, then note both the value and the temperature. Rinse the sensor with clean water between samples so one solution does not skew the next. Check the base water first, then the mixed reservoir, to see how much each additive raises the reading. Spot checks on runoff show whether salts are building in the root zone over time. Myron L calibrates the PT1 at 1,800 µS KCl or 3,000 ppm 442, using its KCL-1800 and 442-3000 standards. Calibrating on a regular schedule keeps the accuracy inside its stated range. The pen runs on one N-type 1.5 V alkaline battery, which comes installed. It draws only 2 µA in sleep mode, so the battery is not wasted between readings. A protective cap, scoop, pocket clip, holster, lanyard and quick start guide come in the box. Myron L backs the pen with a one-year limited warranty, excluding the battery.
Key Features
- Four Readings: Conductivity, TDS, salinity and temperature in one pen.
- 1 to 10,000 µS: Wide range from pure water to strong nutrient solutions.
- ±1% Accuracy: Of reading after wet calibration, ±0.2% at the calibration point.
- Automatic Compensation: Readings corrected to 25°C.
- Five Solution Modes: KCl, 442 and NaCl models for different waters.
- IP67 and NEMA 6: Waterproof anodized aluminum with encapsulated electronics.
- Fast Response: Readings stabilize in 10 to 20 seconds.
- Made in USA: Built by Myron L Company in Carlsbad, California.
Technical Specifications
| Specification | Value |
|---|---|
| Brand | Myron L Company |
| Model | Ultrapen PT1 |
| Conductivity Range | 1 to 10,000 µS (KCl mode) |
| TDS Range | 1 to 10,000 ppm (442 and NaCl modes) |
| Salinity Range | 0.0010 to 10.000 ppt |
| Temperature Range | 32 to 160°F (0 to 71°C) |
| Resolution | 0.1 µS/ppm below 100, 1 µS/ppm from 100 to 10,000 |
| Accuracy | ±1% of reading; ±0.2% at calibration point |
| Temperature Accuracy | ±0.1°C |
| Temperature Compensation | Automatic, to 25°C |
| Stabilization Time | 10 to 20 seconds |
| Calibration Points | 1,800 µS KCl or 3,000 ppm 442 |
| Battery | 1 x N-type 1.5 V alkaline, included |
| Water Rating | IP67, NEMA 6 |
| Case | Anodized aircraft aluminum |
| Dimensions | 6.75 x 0.625 in (17.15 x 1.59 cm) |
| Weight | 55 g (1.94 oz) |
| Operating Temperature | 32 to 131°F (0 to 55°C) |
| Warranty | 1 year limited, battery excluded |
| Made In | USA |