Split AC Line Set Sized for ACANS12 Installations
Every split air conditioner depends on a pair of copper lines to move refrigerant between its indoor and outdoor sections. This set provides that pair for the ACANS12 and the ACANS12V230. Its 25 foot length lets the condenser sit well away from the grow room wall. That extra reach helps when the best outdoor spot is around a corner or across a walkway. One line delivers liquid refrigerant to the indoor coil, where it absorbs heat from the room air. The second line carries the warmed vapor back outside for the compressor to reject. Copper tubing holds refrigerant pressure and can be bent gradually for routing. Insulation sleeves cover the tubing to prevent condensation on the cold return line. Dry lines matter in a grow space, where dripping water feeds mold and raises humidity. Cooling this way keeps the room sealed from outside air, pests and pollen. It also frees exhaust fans to handle odor control instead of heat removal.
Picking the Condenser Location and Protecting the Lines
Choose the outdoor unit's spot before anything else, since it sets the length of the run. A level pad with open airflow on all sides keeps the condenser working efficiently. Mark the indoor head location high on the wall for even air across the canopy. Then confirm the lines can travel between the two points without tight bends. Keep any extra length in gentle loops rather than sharp coils. Leave the end caps on until the technician connects each end. A certified technician should pressure test, evacuate and charge the system. EPA Section 608 certification is required in the United States for that refrigerant work. After installation, inspect the insulation every few months for cracks, gaps or pest damage. Replace or tape damaged sections so the return line stays dry. Keep plants, weeds and debris clear of the lines outdoors. Oily spots on fittings can point to a refrigerant leak and call for a service visit. Well protected lines keep the room cooling steadily through every flowering cycle.
Key Features
- Paired Refrigerant Lines: Liquid and suction lines in one set.
- 25 ft of Tubing: Room to place the condenser away from the wall.
- Insulation Sleeves: Keep the cold return line dry.
- Two Unit Fit: Works with ACANS12 and ACANS12V230.
- Capped Ends: Keep dust and moisture out before connection.

Technical Specifications
| Specification | Value |
|---|---|
| Type | Refrigerant line set for split air conditioner |
| Compatible Units | ACANS12, ACANS12V230 |
| Length | 25 ft |
| Material | Copper tubing |
| Insulation | Insulated lines |
| Lines Included | Liquid line and suction line |
| Item Number | ACANS12LS |