Skip to product information
1 of 1
Brand: *AAA NO Brand

25 ft Insulated Copper Line Set for ACANS24 24,000 BTU Split A/C

25 ft Insulated Copper Line Set for ACANS24 24,000 BTU Split A/C

SKU: SKU:ACANS24LS

Ordering a large quantity of this item?
As long as the order total is more than $2K you can:

Regular price $228.88 USD
Regular price Sale price $228.88 USD
Sale Sold out
Shipping calculated at checkout.

KILLER PRICE
This item is heavily discounted and may not qualify for discounts.

This copper line set connects the indoor and outdoor halves of the ACANS24 24,000 BTU split air conditioner. It supplies 25 feet of insulated copper tubing for both the liquid and suction lines. A certified HVAC technician should make the final refrigerant connections.

View full details

ACANS24 Copper Line Set, 25 ft Insulated Tubing

A split air conditioner needs two refrigerant lines running between the indoor air handler and the outdoor condenser. This set supplies both lines for the ACANS24, a 24,000 BTU split A/C unit. Each line is copper tubing covered in a layer of insulation. The full length is 25 feet, which sets the maximum distance between the two halves of the system. The smaller liquid line carries refrigerant from the condenser to the indoor coil. The larger suction line returns refrigerant vapor to the compressor outside. Insulation keeps the cold suction line from sweating and dripping onto walls or benches. It also limits heat pickup as the refrigerant passes through warm spaces. With the condenser outdoors, compressor heat stays away from the canopy. A split system also cools the room without pulling in outside air. That suits sealed rooms running CO2 enrichment, where every air exchange wastes gas. The cooling load moves outside while the grow space stays closed.

Installing the AC Line Set in a Grow Room

Plan the route before drilling any holes through walls or ceilings. Measure the path from the indoor head to the condenser pad, counting every bend and rise. The lines should reach both units without stretching or sharp turns. Bend the copper gradually by hand or with a tube bender to avoid kinks. A kinked line restricts refrigerant flow and cuts cooling capacity. Leave the protective caps on the ends until the moment of connection. Open ends let in dust and moisture that can harm the system. Support the lines along walls with straps so they do not sag. Seal the wall opening once the lines pass through to block pests and light leaks. Wrap exposed insulation outdoors to shield it from sunlight and weather. Before startup, the lines must be pressure tested and evacuated with a vacuum pump. In the United States, refrigerant work calls for an EPA Section 608 certified technician. Many growers finish mounting and wiring first, then bring in a technician for the final connections.

Key Features

  • Two Copper Lines: Liquid and suction lines in one set.
  • 25 ft Length: Spans the indoor head to the outdoor condenser.
  • Insulated Tubing: Limits condensation and heat gain along the run.
  • Made for ACANS24: Matches the 24,000 BTU split A/C unit.
  • Heat Stays Outside: Lets the condenser sit outdoors, away from the canopy.
ACANS24 insulated refrigerant lines, coiled with capped ends

Technical Specifications

Specification Value
Type Refrigerant line set for split air conditioner
Compatible Unit ACANS24 24,000 BTU split A/C
Length 25 ft
Material Copper tubing
Insulation Insulated lines
Lines Included Liquid line and suction line
Item Number ACANS24LS