Agrowtek 3-Port Sensor Manifold for Inline Probes
The PBX-310 is a three-port sensor manifold that puts pH, EC, ORP or DO, and temperature probes inline with a recirculating pump. Three water-tight compression glands are built into a 1 in PVC body. Each gland has a sleeve insert that clamps around the probe as it tightens. One end is 1 in NPT male and the other is 1 in NPT female with an O-ring, so it threads into standard plumbing. The assembly measures 12 in long and 3.75 in tall. It is rated to 90 PSI and 30 GPM. Probes slide in and out at the gland, which keeps installation, calibration and replacement simple. Reading the water as it moves gives a number that represents the whole loop rather than one corner of a tank. Sensing inline also keeps probes out of the reservoir, where roots and debris can foul them. It pairs with PBX injection manifolds when dosing shares the same pipe run. Agrowtek builds it in the USA and backs it with a one-year warranty.
Plumbing a Hydroponic Manifold Into a Recirculating Loop
Plumb it on a loop that runs whenever you want a reading, usually a side loop off the recirculating pump. Each probe tip must stay off the manifold wall, so set the depth before tightening the gland. Tighten each gland by hand until the sleeve grips, then check for weeps once the pump runs. Mount it with the ports facing up so trapped air does not sit on the sensing tips. Stay inside the flow rating, and put a larger pump on a bypass instead of through the manifold. Isolation valves on both sides let you service a probe without draining the whole system. Calibrate on the usual schedule by loosening the gland and lifting the probe out. Pair it with a controller that logs pH, EC and temperature, so the live readings become trend data. The honest limit is that the manifold holds probes but does not include them. Sensors, controller and cables are separate, so plan the full monitoring setup before plumbing it in.
Key Features
- Three Compression Glands: Sleeve inserts clamp pH, EC, ORP or DO and temperature probes water-tight.
- 1 in PVC Body: The manifold threads into standard 1 in plumbing at both ends.
- Male and Female NPT Ends: One 1 in NPT male end and one 1 in NPT female end with an O-ring.
- 90 PSI, 30 GPM Rating: It handles the pressure and flow of a typical recirculating loop.
- Easy Probe Access: Loosen a gland to pull a probe for calibration or replacement.
Technical Specifications
| Specification | Value |
|---|---|
| Model | PBX-310 |
| Ports | 3 compression glands with sleeve inserts |
| Compatible probes | pH, EC, ORP/DO, water temperature |
| Body | 1 in PVC |
| Connections | 1 in NPT male; 1 in NPT female with O-ring |
| Length | 12 in |
| Height | 3.75 in |
| Maximum pressure | 90 PSI |
| Maximum flow | 30 GPM |
| Optional accessories | PBX injection manifolds |
| Made in | USA |