Anden A710V1 VLGR Industrial Dehumidifier, 710 Pints per Day, 208-240V

Anden A710V1 VLGR Industrial Dehumidifier, 710 Pints per Day, 208-240V

SKU: SKU:DHA710V1

Ordering a large quantity of this item?
As long as the order total is more than $2K you can:

Regular price $9,337.50 USD
Regular price $9,337.50 USD Sale price $9,337.50 USD
Sale Sold out
Shipping calculated at checkout.

The Anden A710V1 dehumidifier removes 710 pints of water a day on a single 30 A, 208-240V circuit. VLGR technology modulates the refrigeration system to the moisture load, and a 1,760 CFM blower moves air through a MERV 11 filter.

View full details

Anden A710V1 Dehumidifier: 710 Pints a Day With VLGR Control

The Anden A710V1 dehumidifier is a large-capacity refrigerant unit built for indoor growing rooms. It removes 710 pints of water a day at 80°F and 60 percent RH. Efficiency is rated at 3.0 L/kWh, or 6.35 pints per kWh. Anden's VLGR technology modulates the refrigeration system based on the moisture load in the room. That load matching gives tighter control of VPD, especially under late flower conditions. Air crosses a copper-tube, aluminum-fin coil with an i-coat finish before it is reheated and discharged. The blower moves 1,760 CFM in free air and still holds 1,510 CFM against 0.6 inches of water column static pressure. Power is 208-240V single phase at 19.6 A and 4,706 W. A 10 ft SJT cord ends in a NEMA L6-30P locking plug on a 30 A breaker. For hard-wiring, Anden calls for 10 gauge copper wire. Total heat load into the room is 16,168 Btu/h. The cabinet measures 44.875 in wide, 34.4 in high and 31.7 in long, and it weighs 360 lb. Hanging brackets are built into the cabinet. A 29.5 x 31.5 x 1.75 in MERV 11 filter, part 5852, protects the coil. The Model A77 control, a P-trap with vent tee and fittings, and 30 ft of thermostat wire come in the box. Anden covers all parts, including the refrigeration system, for five years.

Installing a Variable Speed Dehumidifier in a Grow Room

Plan at least 18 in of clearance on the inlet side and around the cabinet. Do not aim the outlet of one unit at the inlet of another. Keep the unit away from HVAC returns and supply registers so the two systems do not fight. To hang it, run 3/8 or 1/2 in threaded rod to the built-in brackets. Double-nut the bottom of each rod with a flat washer, and use a single nut on top. Vibration isolators are optional where noise matters. Level the unit front to back and side to side before connecting the drain. The cabinet runs under negative pressure, so it needs the included vented drain and P-trap. The vent must rise higher than the filter frame. Run the drain line with a constant downward slope to a floor drain or condensate pump. Support the line so it cannot dip or sag, and never submerge its end in water. Do not double trap the line, and prime the trap once installation is complete. Add a vacuum break when the drain feeds a condensate pump or joins other drain lines. Floor installs use the 5789 leveling feet kit, and ducted installs use duct kit 5859. The A77 sets humidity between 35 and 80 percent RH and turns the unit off 3 percent below the setting. Any external control with a dry contact closure can replace it. Anden rates the operating range from 60°F at 40 percent RH to 85°F at 80 percent RH.

Key Features

  • 710 pints per day: At 80°F and 60% RH, 3.0 L/kWh.
  • VLGR technology: Modulates refrigeration to the moisture load.
  • 30 A circuit: 208-240V, 19.6 A, NEMA L6-30P cord or hard-wire.
  • 1,760 CFM blower: 1,510 CFM still delivered at 0.6 in w.c.
  • Built-in hanging brackets: Takes 3/8 or 1/2 in threaded rod.
  • Model A77 included: Or any dry-contact external control.
  • Vented drain kit: P-trap, vent tee and fittings included.
  • Five-year warranty: All parts, including the refrigeration system.

Technical Specifications

Specification Value
Brand Anden
Model A710V1
Capacity 710 pints/day at 80°F, 60% RH
Energy factor 3.0 L/kWh (6.35 pints/kWh)
Voltage 208-240V, 1 phase, 60 Hz
Current draw 19.6 A
Power 4,706 W
Heat load 16,168 Btu/h
Power cord SJT, NEMA L6-30P, 10 ft; hard-wire field-configurable
Breaker size 30 A
Wire size 10 gauge copper
Airflow 1,760 CFM at 0.0 in w.c.; 1,677 at 0.2; 1,593 at 0.4; 1,510 at 0.6
Control Onboard digital with diagnostics; Model A77 included; dry-contact external control supported
Filter 29.5 x 31.5 x 1.75 in, MERV 11 (part 5852)
Refrigerant R410A
Coil Copper tube, aluminum fin, i-coat
Drain 3/4 in FNPT; vented drain and P-trap required (included)
Included Model A77 control, 3/4 in P-trap, vent tee and drain fittings, 30 ft 4-wire thermostat cable
Hanging brackets Built-in
Leveling feet Kit 5789 (sold separately)
Duct kit Part 5859 (sold separately)
Operating range 60°F/40% RH to 85°F/80% RH
Clearance 18 in minimum
Dimensions 44.875 W x 34.4 H x 31.7 L in
Weight 360 lb
Certifications ETL listed
Warranty 5 years, all parts including refrigeration system
UPC 810038560021