Skip to product information
1 of 2
Brand: Dramm

Dramm Mechanical Thermostat for Greenhouses | T41 Single or T42 Two Stage

Dramm Mechanical Thermostat for Greenhouses | T41 Single or T42 Two Stage

SKU: SKU:T41

Ordering a large quantity of this item?
As long as the order total is more than $2K you can:

Need help building a custom IPM program?
For more guidance on your pest control solutions:

Regular price $107.66 USD
Regular price Sale price $107.66 USD
Sale Sold out
Shipping calculated at checkout.

Option

Holds heating, cooling or ventilation at a dial setting in wet, dusty grow spaces, using a stainless steel coil and an IP54 PVC case. The Dramm mechanical thermostat is a rugged greenhouse thermostat with accuracy to 1°C, in single stage or two stage versions.

View full details

Dramm Mechanical Thermostat Built for Rough Rooms

This is a dial-set mechanical control for heating, cooling and ventilation in greenhouses, farm buildings and warehouses. A stainless steel coil sits outside the case and reads the air directly, with no separate probe to wire. Accuracy runs to 1°C, and the working range covers 30 to 104°F (0 to 40°C). Each stage switches through an SPDT contact, so one side opens on a temperature rise as the other closes. That gives you a heat or cool output from the same unit, depending on the terminal you wire. Contacts are rated to 15 A non-inductive and 4 A inductive. Larger motors and heater banks should switch through a relay or contactor rather than directly. The PVC case carries an IP54 rating, and the wiring enters through a water tight connector. It handles spray and drips well, but it isn't a sealed unit. Never mount it where it could sit under water.

A Greenhouse Thermostat Placed Where the Plants Are

Placement matters more than anything else on this greenhouse thermostat, because the coil only knows the air around it. Mount it at plant height toward the center of the growing area, not on an endwall or a sidewall. Keep it shaded from direct sun and clear of heat pipes and duct outlets, which would skew the reading. Run the ground wire to its clip first, then land the control wiring on the terminals shown in Dramm's drawings. Check the dial against an accurate thermometer once it is installed. To recalibrate, line up the dial mark with the true temperature. Then grip the outside of the knob and rotate the star-shaped center until it clicks. The dial then reads true against that thermometer. There is no display, no data log and no remote access here. What you get instead is a control with almost nothing to fail in a wet, dusty room. Plan on a switching differential of about one degree Celsius when you set it, so equipment doesn't short cycle around a tight target. Follow local electrical codes on every install.

Key Features

  • Stainless Steel Coil Sensor: Reads the air directly and resists corrosion in humid, harsh rooms.
  • 30 to 104°F Range: Covers both a winter heating setpoint and a summer fan setpoint on the same dial.
  • Accuracy to 1°C: Keeps heaters and fans working close to the number you set.
  • SPDT No-Load Contacts: One contact opens as the other closes, so one unit can drive either heating or cooling.
  • 15 A Non-Inductive, 4 A Inductive: Handles small loads directly, with a relay or contactor for bigger motors.
  • IP54 PVC Case: Non-corrosive housing that shrugs off spray and drips in a working greenhouse.
  • Water Tight Wiring Connector: Keeps moisture from following the cable into the terminals.
  • Field Calibration: A star-shaped knob resets the dial against an accurate thermometer in seconds.

Technical Specifications

Specification Value
Models T41 single stage, T42 two stage
Temperature Range 30 to 104°F (0 to 40°C)
Accuracy 1°C
Differential Approximately 1°C
Contacts 1 SPDT (T41), 2 SPDT (T42), no load
Sensor 1 stainless steel coil (T41), 2 stainless steel coils (T42)
Non-Inductive Load 15 A
Inductive Load 4 A
Enclosure PVC, IP54
Wiring Entry Water tight connector
Use Heating, cooling and ventilation control