Gard'nClean Fast Release Chlorine Dioxide Generator for Sealed Rooms
Gard'nClean Fast Release turns a sealed room into a full-volume deodorizing treatment with nothing more than water. Inside the cup sits a sachet of dry sodium chlorite and proprietary reactants. Adding water starts a reaction that releases pure chlorine dioxide gas into the room. Because it is a true dry gas, it moves into places a spray or wipe never reaches. Gard'nClean lists microscopic openings in unsealed materials, HVAC ducting and electrical components among them. No fogger, sprayer or power source is needed. The product is made to deodorize and improve air quality in enclosed spaces. It is not EPA-registered and makes no disinfection or kill claims. Each size is rated by room volume in cubic feet. Measure length, width and height, multiply them, and match the result to the size on the label. One container treats an enclosed area up to its rated volume. Larger rooms take several containers spaced evenly on flat surfaces.
Running a Treatment With This ClO2 Odor Eliminator
Plan the treatment for an empty room, because the gas is not safe around people or plants. Clean surfaces first, since the maker recommends a wipe-down before any gas treatment. Turn off the lights and close the blinds, as chlorine dioxide breaks down in light. Seal the room so the gas stays inside it. Set the cup in the center of the room, as high as possible. The gas is heavier than air, so keep it off the floor and away from tables. Fans help spread it evenly through the space. Wearing a NIOSH or MSHA approved respirator rated for chlorine dioxide, remove the sachet from its foil pouch without tearing it. Place it in the cup, add water to the fill line and leave the room right away. Hang a do-not-enter sign on the door. Stay out for at least 4 hours, though a full 12 hours gives the strongest result. Ventilate for at least an hour before anyone returns without a respirator. Pour the leftover liquid down a drain and put the spent sachet in the trash.
Key Features
- Water Activated: Add water to the cup to start chlorine dioxide release.
- True Dry Gas: Reaches ducting, gaps and porous surfaces that a spray misses.
- No Equipment: No fogger or power is needed for a whole-room treatment.
- Sized by Volume: Choose 2,500, 4,000 or 10,000 cu ft per container.
- Simple Disposal: Leftover liquid goes down a drain and the sachet goes in the trash.
Technical Specifications
| Specification | Value |
|---|---|
| Type | Water-activated chlorine dioxide gas generator |
| Dry Ingredients | Sodium chlorite and proprietary ingredients |
| Activated Product | Chlorine dioxide gas |
| Coverage | 2,500, 4,000 or 10,000 cu ft per container (by size) |
| Treatment Time | 4 hours minimum, 12 hours for best results |
| Re-Entry | Ventilate at least 1 hour |
| PPE | NIOSH/MSHA-approved respirator for chlorine dioxide |
| Intended Use | Deodorizing and air quality; not EPA-registered |
| Models | GC25KFR, GC40KFR, GC-10K-FR |