The Growlink ClimaLINK climate sensor delivers canopy-level temperature, humidity, light, and VPD readings — with an optional 0–5000 ppm CO₂ module — over an aspirated sensor head that actively pulls air across the probes for stable data. As a Growlink OS-connected grow room climate sensor, it feeds the same hub that handles logging, alerts, and equipment automation.

View full details

Growlink ClimaLINK climate sensor for aspirated canopy monitoring

The ClimaLINK reads canopy air at -40 to 257°F (-40 to 125°C) ±0.18°F and 0–100% RH ±1.0%, then derives VPD on board so the values that drive transpiration arrive already calculated at the Growlink hub. Passive sensors stall in dense canopies. The aspirated head pulls a steady stream of air across the probes, which matters when leaf-height microclimates form around the housing and a static sensor ends up reading the dead spot instead of the actual canopy.

Two configurations for any grow room climate sensor build

GL-LINK-CLIMATE covers temp, humidity, light, and VPD; GL-LINK_CLIMATECO2 adds an NDIR 0–5000 ppm CO₂ sensor at ±3% accuracy for rooms actively dosing CO₂. Both share the same 9.25" × 4.375" × 3.75" housing with sealed filters over the intakes, which matters less in a clean propagation room than in a flowering room where overspray and root-zone dust eventually creep into exposed probes. Hang it at leaf height, run the included 5m M8 cable to the hub, and the readings feed the same Growlink OS pipeline that handles irrigation, substrate VWC, and climate setpoints.

Key Features

  • Aspirated Sensor Head: Active airflow across the probes keeps readings honest in dense canopies where passive sensors stall on stale air pockets.
  • Built-in VPD Calculation: Vapor pressure deficit arrives pre-computed at the hub, so Growlink OS plots VPD without an extra calculation layer on the dashboard.
  • Optional NDIR CO₂ Module: The CLIMATECO2 SKU adds 0–5000 ppm sensing at ±3% accuracy, sized for rooms running active CO₂ enrichment up to typical flowering targets.
  • Wide Temperature Range: -40 to 257°F (-40 to 125°C) at ±0.18°F resolution covers propagation cold rooms through greenhouse summer peaks without switching probes.
  • Sealed Filter Construction: Filters over each intake keep media dust and irrigation overspray off the sensor element across a full flowering cycle.
  • 5m M8 Cable Included: Pre-terminated cable runs from the ClimaLINK to the Growlink hub without a custom harness or field-built connector.
  • Growlink OS Integration: Data drops into the same dashboard, logging, and automation rules as Growlink's irrigation and substrate sensors.

Technical Specifications

Specification Value
Temperature Range -40 to 257°F (-40 to 125°C)
Temperature Accuracy ±0.18°F (±0.1°C)
Humidity Range 0–100% RH
Humidity Accuracy ±1.0%
CO₂ Range (CLIMATECO2 SKU) 0–5000 ppm
CO₂ Accuracy (CLIMATECO2 SKU) ±3%
Light Measurement Included
VPD Calculation On-sensor
Sensor Design Aspirated
Dimensions 9.25" × 4.375" × 3.75"
Cable Included 5m M8
Compatible System Growlink OS
SKUs GL-LINK-CLIMATE / GL-LINK_CLIMATECO2