Powering LINKS Modules with the Growlink LINK Power Supply 1A
The Growlink LINK Power Supply 1A delivers regulated 24VDC at 1 amp to any single-port LINKS module that fits that draw. The HUB sits squarely inside that budget. So does the batch tankLINK at its rated working load. The unit accepts 100–240VAC universal input. It ships with a set of international plug adapters covering US, EU, UK, and AU outlets. No separate converter required for moves between facilities. Plug-and-play means the DC connector lands on the module's labeled input on the first try, with no rewiring or pin matching.
Sizing the 24VDC Power Adapter to the Right LINKS Device
Use this 1A LINKS power supply for replacement, redundancy, or international travel between facilities. Growers running multiple HUBs across rooms often keep a spare on the shelf so a dead brick doesn't pull a controller offline mid-run. If you're powering a valveLINK or another higher-draw LINKS device, check the spec sheet first. The valveLINK pulls 2.7A, and the relayLINK pulls 1.5A. Neither lands inside this 24VDC power adapter's 1A budget. Those need the 3A LINK Power Supply instead. Match the Growlink LINK PSU current to the device, and the system stays stable through transient loads on every output the module drives. Keep one labeled by room so a swap during a service window takes seconds. The unit's compact size fits inside most controller boxes without dedicated mounting space. That makes it easy to tuck against the wall behind a HUB or under a bench when the cable run is short.
Key Features
- 24VDC Regulated Output: Matches the HUB and batch tankLINK input spec — drops in as the labeled DC connector on either module.
- 1A Current Budget: Sized for single-port LINKS devices that draw within 1 amp — not the valveLINK (2.7A) or relayLINK (1.5A).
- 100–240VAC Universal Input: Runs on any standard residential or commercial circuit worldwide without a separate voltage converter.
- International Plug Adapters: Ships with US, EU, UK, and AU plug heads — same brick travels between facilities across regions.
- Plug-and-Play DC Connector: Lands on the LINKS module's labeled input on the first try — no rewiring, no adapter cables.
Technical Specifications
| Specification | Value |
|---|---|
| Output | 24VDC, 1A (regulated) |
| AC Input | 100–240VAC universal |
| Plug Heads Included | US, EU, UK, AU |
| Connector | LINKS-native DC barrel into module's labeled input |
| Compatible LINKS Devices | HUB (24VDC / 1A), batch tankLINK (24VDC working load) |
| Not Sized For | valveLINK (2.7A) and relayLINK (1.5A) — use the 3A LINK Power Supply |