Skip to product information
1 of 2
Brand: Hanna Instruments

Hanna GroLine HI98331 Direct Soil EC Tester | Penetration Probe

Hanna GroLine HI98331 Direct Soil EC Tester | Penetration Probe

SKU: SKU:HI98331

Ordering a large quantity of this item?
As long as the order total is more than $2K you can:

Regular price $164.99 USD
Regular price Sale price $164.99 USD
Sale Sold out
Shipping calculated at checkout.

KILLER PRICE
This item is heavily discounted and may not qualify for discounts.

Availability: Online | Will Call Locations Stock May Vary

A direct soil EC meter that reads straight out of the substrate, no slurry required. The stainless steel penetration probe goes into moist soil and returns a temperature-compensated conductivity reading on one button.

View full details

What a Direct Soil EC Meter Saves You

The old routine was a slurry. Take a sample, mix it with distilled water at a set ratio, wait, filter, then read the extract. It works, and it takes long enough that most people skip it. The HI98331 puts a stainless steel penetration probe into the substrate and reads it where it sits. Range runs 0 to 4000 uS/cm, resolution 1 uS/cm. One button, one-point calibration, done automatically against a 1413 uS/cm standard.

Bulk EC, and What a Soil Conductivity Tester Is Really Telling You

This is worth being precise about. What comes back is bulk EC. That is the conductivity of everything in the sample together, meaning the soil particles, the water in the pores and the air between them. It is not the same number as a saturated paste extract, and comparing the two directly will mislead you. Bulk EC is still the reading you want for tracking, because it moves when your feed moves. Knowing water content lets you calculate pore water conductivity from it. A soil conductivity tester also needs moist soil to read at all, since dry substrate has nothing conductive to bridge the pins. Rinse the probe with deionized water and dry it before each reading. Make the hole with an auger or a ruler so depth stays consistent between spots. Temperature compensation is automatic on a fixed 2% per degree coefficient, using the integrated sensor.

Key Features

  • Reads straight out of the substrate: The stainless penetration probe removes the slurry step, which is the step most people skip.
  • 0 to 4000 uS/cm range: Resolution of 1 uS/cm, with accuracy of +/- 50 uS/cm across the lower half of the scale.
  • Automatic temperature compensation: An integrated sensor corrects every reading on a fixed 2% per degree coefficient.
  • One-point automatic calibration: Recognises the 1413 uS/cm standard on its own, on a single button.
  • 114 mm penetration electrode: Long enough to reach past the surface layer into the root zone where the number matters.
  • Roughly 100 hours on a CR2032: With a storage and protection sleeve for the probe between readings.

Technical Specifications

Specification Value
Model Hanna GroLine HI98331
Conductivity Range 0 to 4000 uS/cm; 0.00 to 4.00 mS/cm (dS/m)
Conductivity Resolution 1 uS/cm; 0.01 mS/cm
Conductivity Accuracy +/- 50 uS/cm (0-2000), +/- 300 uS/cm (2000-4000)
Temperature Range 0.0 to 50.0 C
Temperature Resolution 0.1 C
Temperature Accuracy +/- 1 C
Calibration Automatic one-point at 1.41 mS/cm
Temperature Compensation Automatic, fixed 2% per C coefficient
Electrode 114 mm (4.5 in) stainless steel penetration probe
Battery CR2032 Li-ion, approx 100 hours continuous
Dimensions 50 x 196 x 21 mm (2.0 x 7.7 x 0.9 in)
Weight 74 g (2.4 oz)
Environment 0 to 50 C (32 to 122 F), RH max 95% non-condensing
Included Penetration probe, CR2032 battery, storage sleeve, manual, quality certificate
Warranty 1 year