Skip to product information
1 of 1
Brand: Netafim

Netafim Backflush Controller, 6 Outputs With DP Sensor, 24VAC, With Mounting Bracket

Netafim Backflush Controller, 6 Outputs With DP Sensor, 24VAC, With Mounting Bracket

SKU: SKU:00105-006220

Ordering a large quantity of this item?
As long as the order total is more than $2K you can:

Regular price $1,070.77 USD
Regular price Sale price $1,070.77 USD
Sale Sold out
Shipping calculated at checkout.

This Netafim disc filter backflush controller sequences six 24VAC flush valves from a 110 or 220 volt supply. Its embedded DP sensor, interval timer and cycle counters keep a six-filter battery clean, and a bracket is included.

View full details

Netafim Disc Filter Backflush Controller for Six-Filter Batteries

A long disc filter battery at an irrigation head loads up faster than any one person can watch it. Netafim model 31NBCAC6, item 00105-006220, flushes up to six of those filters one after another on 24VAC solenoids. A built-in supply converts 110 VAC at 60 Hz or 220 VAC at 50 Hz to the 24 volts the coils need. The six outputs come on three plug-in cards, and Netafim's 2-output AC card, model 31NBCACCARD, adds more up to 10. Flushing begins when the embedded sensor sees the pressure drop reach its set point, or when the interval timer runs out. Netafim also lists the controller for automatic sand media and screen filters. Pressure shows in bar or psi, chosen during configuration. The set point covers 0.1 to 2.0 bar, which equals 1 to 30 psi. A downstream pressure sustaining valve, a delay valve and an alarm can each be given an output. The controller weighs 1.3 lb and comes with its mounting bracket.

Reading the 6 Station 24VAC Flush Controller Display

The top of the LCD shows actual DP, with the DP set point beneath it. Flush time per station sits at the lower left, and the flush mode at the lower right. Flush mode reads OFF, a time interval, or dp when only the sensor starts cycles. Hold the plus and minus keys together to see the time left until the next flush. A dedicated icon appears whenever a cycle has been started by hand from the MANUAL key. Three running totals record cycles started by DP, by the timer and by hand. Clear any of them with the plus or minus key when starting a new season's log. The final configuration screen gives the controller's software version for service calls. A blinking P means the low-pressure input has closed and the controller has paused. Operation is rated from 32 to 140°F, and the housing stands 9-1/2 in tall.

Key Features

  • Six 24VAC outputs: Three plug-in cards; up to 10 with 31NBCACCARD.
  • 110 or 220 VAC supply: Built-in conversion to 24VAC.
  • Embedded DP sensor: Set point 0.1-2.0 bar or 1-30 psi.
  • Clear LCD readout: Actual DP, set point, flush time and mode on one screen.
  • Three cycle counters: Separate totals for DP, timed and manual flushes.
  • Mounting bracket: Comes with the controller.

Technical Specifications

Specification Value
Item Number 00105-006220
Model 31NBCAC6
Outputs 6, 24VAC solenoids
Expansion Up to 10 outputs with 31NBCACCARD 2-output cards
Power Source 110 VAC 60 Hz or 220 VAC 50 Hz, built-in 24VAC supply
DP Input Embedded electronic analog DP sensor or external dry-contact DP switch
DP Set Point 0.1-2.0 bar (1-30 psi)
Pressure Units Bar or psi
Flush Mode Off, time interval (5 min to 120 h) or DP only
Flush Time per Station 5 s to 6 min
Dwell Between Stations 5-60 s
DP Delay 5-60 s
Optional Outputs Main / pressure sustaining valve, delay valve, alarm
Operating Temperature 32-140°F (0-60°C)
Dimensions 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
Weight 1.3 lb
Included Mounting bracket