Skip to product information
1 of 1
Brand: Netafim

Netafim Hanging Sprinkler, Mister or Fogger Assembly, 36 in, 150 Pack (0300HSAC-36)

Netafim Hanging Sprinkler, Mister or Fogger Assembly, 36 in, 150 Pack (0300HSAC-36)

SKU: SKU:63000-007160

Ordering a large quantity of this item?
As long as the order total is more than $2K you can:

Regular price $216.92 USD
Regular price Sale price $216.92 USD
Sale Sold out
Shipping calculated at checkout.

This carton holds 150 Netafim hanging bases for a greenhouse fogger assembly, each dropping the head 36 in below a polyethylene supply pipe. Every base carries Super Flex UV White tubing, a stabilizer weight and a female connector for the fogger.

View full details

Netafim Greenhouse Fogger Assembly Bases, 36 in, 150 Pack

Fogging a whole house for humidity or cooling hangs heads high and spreads them across the full floor. This carton, Netafim item 63000-007160 and model 0300HSAC-36, packs 150 hanging bases for that work. Each base suspends its head on 36 in of Super Flex UV White polyethylene tubing, 4/7 mm in size. A barb at the top inserts into the polyethylene supply pipe. The lower end has a barb x female connector that receives the fogger, mister or sprinkler. A white stabilizer weight keeps each head hanging straight under the pipe. Because the heads hang below the pipe, drips from the pipe stay off the crop. The fully opaque tube keeps algae from growing inside. It resists UV, heat, direct sun and harsh chemicals, and the white surface reflects heat to keep the water cooler. Every part fits together by hand, and heads are supplied separately.

Cooling a House With Foggers on a 36 Inch Hanging Tube

For cooling, hang CoolNet Pro foggers 3 to 6 ft high, and higher is generally better. Fogger spacing runs from 3 to 10 ft along a line, with lines 6.5 to 13 ft apart. Keep the fog from spraying against the roof or structure. Adjust the cycle so the fog evaporates without falling as precipitation on the crop. Exhaust fans exchanging the air about 20 times per hour get the most cooling out of the fog. With foggers 5 ft apart on lines 10.5 ft apart, start at a 3 second pulse every 91 seconds. At 10 ft by 10 ft, the starting point is a 10 second pulse every 150 seconds. Crops that tolerate wetting can take a longer pulse or a shorter interval. Fine-tune both to local conditions, since these timings are only a starting point. Run fogger zones through a 65 psi regulator and a 140 mesh filter.

Key Features

  • 150 per carton: For whole-house fogging layouts.
  • 36 in drop tube: Super Flex UV White PE, 4/7 mm.
  • Stabilizer weight: Keeps each fogger plumb.
  • Barbed PE inlet: Inserts into the supply pipe.
  • Female head connector: Takes CoolNet Pro foggers and other Netafim heads.

Technical Specifications

Specification Value
Item Number 63000-007160
Model 0300HSAC-36
Tube Length 36 in
Tubing Super Flex UV White PE, 4/7 mm
Inlet Barb x barb connector for PE supply pipe
Head Connection Barb x female connector
Stabilizer Weight Included
Carton Quantity 150
Heads Included No