Netafim Pressure Regulating Unit 35 psi

Irrigation zones rarely see the same pressure all day, as demand elsewhere on the line pulls supply up and down. A regulator evens that out, and the sealed unit inside sets the number it holds. This module is preset to 35 psi. It has no adjustment screw and nothing to recalibrate, which keeps the setpoint fixed over time. Netafim makes a separate sealed unit for each pressure in the range. This one fits the 3/4 inch high flow regulator as a single module. Two of them load into the 1 1/2 inch dual module regulator. Four of them fill the 2 inch four module regulator. Changing the module renews the regulator without replumbing the zone. Inside the Netafim regulator line, a stainless steel spring works against an EPDM diaphragm. Bodies are built from plastic and brass that will not corrode. The line is rated for operating pressures up to 145 psi. Choose 35 psi when the emitters or sprinklers on the zone are specified for that working pressure. Keep the same module rating across every regulator feeding a given zone.

Replacing an Irrigation Pressure Regulator Module

Close the valve feeding the regulator and bleed off pressure first. Open the regulator housing as described in the Netafim instructions for that size. Pull the old regulating unit straight out. Look over the seat and seals for debris, scale or wear. Set the new unit in the same position as the old one. Dual and four module housings need every module at the same pressure rating. Close and hand-tighten the housing fully. Open the supply valve slowly so the new diaphragm is not shocked. Watch a downstream gauge until pressure settles at the module rating. If it reads far off, check for a missing seal or debris on the seat. Keep a screen or disc filter upstream to protect the module. Record the install date so the next replacement can be planned.

Key Features

  • 35 psi Preset: Fixed setpoint with nothing to adjust.
  • Sealed Module: One-piece unit, swapped in the field.
  • Three Housing Fits: Single, dual and four module Netafim regulators.
  • Steady Zones: Holds outlet pressure as supply changes.
  • Rated Regulator Line: Up to 145 psi operating pressure.
Netafim 35 psi sealed regulating module

Technical Specifications

Specification Value
Brand Netafim
Type Sealed pressure regulating unit (replacement module)
Preset Outlet Pressure 35 psi
Item Number 31500-001600
Fits Netafim 3/4 in high flow regulator (1 module), 1 1/2 in dual module regulator (2 modules), 2 in four module regulator (4 modules)
Housing Flow Ranges 3/4 in high flow: 4.5 to 17.5 GPM; 1 1/2 in: 11 to 35 GPM
Regulator Max Operating Pressure 145 psi
Regulator Materials Plastic and brass body, stainless steel spring, EPDM diaphragm
Service Field replaceable, one-piece sealed unit