This is a temperature and humidity controller that drives two pieces of equipment from two outlets, one per condition. Both readings come from external probes on a lead rather than from a sensor inside the case. It holds separate day and night targets and works out which applies on its own. Rated figures are 120 volts, 15 A and a two horsepower total load.

View full details

How a Two Outlet Temperature and Humidity Controller Divides the Work

One outlet for the condition you are heating or cooling, one for the condition you are wetting or drying. That split is the whole design, and it is why this unit replaces two separate single task controllers. Each outlet has its own target, so a heater and a dehumidifier stop fighting each other for the same reading. It runs cooling, heating, humidifying, dehumidifying, or cooling and dehumidifying together. Electrically it is 120 volts at 15 A, with a total load ceiling of 2 HP across both outlets. That ceiling is the number to check first, because two large machines will exceed it long before the outlets do. Day and night detection is built in, and each period carries its own pair of set points. Operation priority is adjustable, which decides what happens when both conditions call at once. So is the shutdown delay, which is what keeps a compressor from restarting into its own back pressure.

Why the External Probe Placement Decides Your Readings

An external probe on a lead is the reason this unit reads the room instead of reading itself. A controller with the sensor inside its own case sits on a wall warmed by whatever is behind it. Accuracy is plus or minus one degree Celsius on temperature and plus or minus 3.5 percent on relative humidity. Those tolerances only hold where the probe hangs in moving air at canopy height. Put it in the middle of the space, out of the discharge of anything it switches, and clear of the lights. A probe in a dehumidifier's exhaust will hold the room far wetter than the display claims. The four equipment version of this controller is a separate unit. Anyone who needs to add carbon dioxide control needs a different model again. This one does two jobs properly rather than four approximately.

Key Features

  • Outlets: Two, one for temperature equipment and one for humidity
  • Modes: Cooling, heating, humidifying, drying, or cooling with drying
  • Probes: Both readings from external sensors on a lead
  • Temperature accuracy: Plus or minus one degree Celsius
  • Humidity accuracy: Plus or minus 3.5 percent relative humidity
  • Electrical: 120 volts, 15 A, 2 HP total load
  • Day and night: Detected automatically, with its own set points each
  • Adjustable: Operation priority and shutdown delay
  • Bigger version: A four equipment model exists as a separate unit

Technical Specifications

Specification Value
SKU NBIGS110S
Model iGS-110
Brand Intelligent Growing Systems
Type Combined temperature and relative humidity controller
Equipment controlled Two, on separate outlets
Modes Cooling, heating, humidifying, dehumidifying, or cooling plus drying
Temperature sensor External probe, accuracy plus or minus 1 degree Celsius
Humidity sensor External probe, accuracy plus or minus 3.5 percent
Voltage 120 V
Current 15 A
Total load 2 HP
Day and night control Automatic detection, separate set points each
Adjustable settings Operation priority and shutdown delay
Larger model The four equipment version is a separate product