Titan Controls Atlas 9 CO2 Controller With Two Control Modes
The Atlas 9 is a plug-in digital controller that holds a CO2 set point by switching a generator or a regulator on and off. Its infrared sensor sits at the end of a 15 ft cord, so the reading comes from the canopy rather than the wall. It measures from 400 to 2000 ppm with an accuracy of plus or minus 100 ppm. Two modes cover the two common CO2 sources. PPM Up runs a CO2 generator, or a regulator on a compressed tank, as on and off around the set point. Fuzzy Logic is for regulators and bottled CO2 only, smoothing the output so the room settles near target. A built-in photocell detects lights-off and disables the output at night. From the factory it is set to 1,000 ppm with a 100 ppm dead-band. The output handles 10 A at 120 VAC, 60 Hz. A Min/Max recall shows the lowest and highest reading over the past 24 hours. The unit weighs 1.1 lbs, measures 5 x 2.75 x 3 in, and carries a two-year warranty.
Setting Up a CO2 Controller With Remote Sensor at Canopy Height
Hang the sensor at canopy height in the middle of the room, away from the tank, the burner and the exhaust intake. Mount the controller on the wall with its tab and plug it into a surge protector on a 120-volt circuit. Set the target with the push-and-turn knob, then the dead-band, and pick the mode that matches the gas source. A generator always goes on PPM Up, because Fuzzy Logic is not for use with burners. Keep the total connected load within the amp rating, which usually means one solenoid or one small burner. Calibrate outdoors, away from people, cars and anything else breathing out CO2, by holding the knob for three seconds. The display reads CAL/400 and settles in about ten minutes, and that step repeats every three years. Before a sulfur burner runs, remove the sensor or bag it with the controller off, or the infrared cell will be damaged. Cover the controller during bug-bomb treatments as well. The honest limit is that it is indoor only and dislikes spray. Keep it out of foliar mist and away from heat, within 50 to 95°F and below 95% humidity.
Key Features
- Infrared Remote Sensor: The sensor rides a 15 ft cord so it can hang at canopy height.
- 400 to 2000 ppm Range: It reads CO2 across the full enrichment range with plus or minus 100 ppm accuracy.
- PPM Up and Fuzzy Logic: One mode runs generators or regulators, and the other smooths regulator output on bottled CO2.
- Photocell Night Shutoff: The output switches off automatically when the lights go out.
- Min/Max Recall: The display shows the lowest and highest reading over the last 24 hours.
- 10 A Output at 120 VAC: A single plug-in outlet runs a generator or solenoid up to the rated load.
Technical Specifications
| Specification | Value |
|---|---|
| Model | Atlas 9 (702854) |
| CO2 range | 400 to 2000 ppm |
| Accuracy | +/- 100 ppm |
| Sensor | Infrared, remote, 15 ft cord |
| Modes | PPM Up (generator or regulator), Fuzzy Logic (regulator and compressed CO2 only) |
| Factory settings | 1000 ppm set point, 100 ppm dead-band, calibrate 400 ppm, PPM Up |
| Day/night | Photocell disables output at night |
| Maximum load | 10 A at 120 VAC, 60 Hz |
| Operating temperature | 50 to 95°F |
| Maximum relative humidity | 95% |
| Dimensions | 5 x 2.75 x 3 in |
| Weight | 1.1 lbs |
| Calibration interval | Every 3 years |
| Use | Indoor only |
| Warranty | 2 years |